Procedural characteristics of pulmonary vein isolation with high

$ 11.99

4.6 (638) In stock

Share

The purpose of this study was to investigate the safety and efficacy of high-power short-duration (HP-SD) ablation compared to conventional ablation in patients with atrial fibrillation (AF). We enrolled consecutive 158 drug-refractory symptomatic AF patients (119 males, mean age 63 ± 10 years) who had undergone first radiofrequency pulmonary vein isolation (PVI). PVI was performed using the conventional setting (20–35 W) in 73 patients (Conventional group) and using the HP-SD setting (45–50 W) in 85 patients (HP-SD group). The rate of first pass isolation, remaining gaps after circumferential ablation, dormant conduction, and the radiofrequency application time in each pulmonary vein (PV) were compared between the groups. The first pass isolation ratio was significantly higher in the HP-SD group than in the Conventional group (81% vs. 65%, P = 0.027) in the right PV, but did not differ in the left PV. The remaining gaps were fewer in the right superior PV (4% vs. 21%, P = 0.001) and left inferior PV (1% vs. 8%, P = 0.032) areas, and the radiofrequency application time in each PV was shorter (right PV, 12.0 ± 8.9 min vs. 34.0 ± 31.7 min, P < 0.001; left PV, 10.6 ± 3.6 min vs. 25.7 ± 22.3 min, P < 0.001) in the HP-SD group than in the Conventional group. The use of the HP-SD setting might contribute to improve the first pass isolation rate and to shorten the radiofrequency application time in each PV.

Pulmonary Vein Reconnection No Longer Occurs in the Majority of

ESC 365 - Doctor Zoltan Sallo

High incidence of atrial fibrillation after successful catheter

The relationship between the heparin dosing during catheter ablation

Prospective use of Ablation Index targets improves clinical outcomes following ablation for atrial fibrillation

Approaches to Catheter Ablation for Persistent Atrial Fibrillation

Significance of Contact Force on Esophageal Thermal Injury During Relative High-Power Short-Duration Ablation of Atrial Fibrillation

福島県立医科大学 循環器内科学講座 教室について 研究部門紹介 臨床研究 不整脈

Prospective Randomized Evaluation of High Power during CLOSE-guided Pulmonary Vein Isolation: The POWER-AF Study

Atrio-Esophageal Fistula as a Complication of Percutaneous Transcatheter Ablation of Atrial Fibrillation

Cardiac Arrhythmia Mapping System Clinical Data – RHYTHMIA HDx

Impedance drop predicts acute electrical reconnection of the pulmonary vein-left atrium after pulmonary vein isolation using short-duration high-power exposure

福島県立医科大学 循環器内科学講座 教室について 研究部門紹介 臨床研究 不整脈

Patient flow diagram. O-A time, interruption time of dabigatran oral

Prospective Randomized Evaluation of High Power during CLOSE-guided Pulmonary Vein Isolation: The POWER-AF Study